| Sl.No |
e-Published Date |
Bid Submission Closing Date |
Tender Opening Date |
Title/Ref.No./Tender Id |
State Name |
Corrigendum |
| 11781. |
02-Mar-2026 11:14 AM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Kit Cylinder Head Test Valve to EMD Par [Kit Cylinder Head Test Valve to EMD Part No.40036607]/10264324/106984353 |
Ministry of Railways |
-- |
| 11782. |
02-Mar-2026 10:31 AM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Set of Gaskets for 3/8 / 1/2 air strainer consisting of 3 items as per details given :
[1]. Gasket O/D-12.5, I/D 6.5, thick 1.8mm -Drawing No.Ref. No.4 of CLW Drg.No.0/2/65/440 with latest alteration Qty/Set:01,
[2]. Gasket O/D32, I/D 24, Thick 1.8mm -Drawing No..Ref. No.6 of CLW Drg.No.0/2/65/440 with latest alteration-Qty/Set:01,
[3]. Gasket O/D-46.25, I/D 40.6, Thick 3 + 0.05 or - 0.00mm Drawing No. Ref. No.7 of CLW Drg.No.0/2/65/440 with latest alteration-Qty/Set:01./LD251155A/106984316 |
Ministry of Railways |
-- |
| 11783. |
26-Feb-2026 05:45 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Grade B Drums conforming to Indian Standard IS: 1783 (Part 2): 1988: or latest if any as per specification Enclosed/LY265134/106982253 |
Ministry of Railways |
-- |
| 11784. |
30-Jan-2026 10:48 AM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
PROTECTION TUBE COMPLETE FOR AXLE GUIDE TO ICF DRG NO EMU/M-0-1-011 ALT. h/2. OR LATEST./31261594/106953662 |
Ministry of Railways |
-- |
| 11785. |
26-Feb-2026 05:24 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Straight Union 1/2 inch O.D. TO ICF/DB265137/106982212 |
Ministry of Railways |
-- |
| 11786. |
09-Feb-2026 02:03 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Set of MS Hardware/65255518B/106963575 |
Ministry of Railways |
-- |
| 11787. |
09-Feb-2026 12:54 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
DRYER 200SCFM W/-40 PDP, AS PER LORAM PART NO. 158627, MAKE: SULLIVAN PALATEK, As per Sullivan Palatek Part No: SP-650110, ACCEPTABLE MAKE: LORAM, SULLIVAN PALATEK./66259306A/106963419 |
Ministry of Railways |
-- |
| 11788. |
30-Jan-2026 11:06 AM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
1 KVAR metalized polypropylene gas filled, wavy cut three phase self-healing type capacitor, rated at 480 V, 50hz, rated current 1.2 amps. capacitor should have discharge resistor and over pressure disconnection. as per RDSO modification sheet no. RDSO/PE/MS/AC/0054-2014 Rev-1 and confirming to IS:13340(Part-1): 2021/IEC 60832-1:2002 with ISI mark suitable for capacitor bank of LHB AC coach. Acceptable makes: Epcos or Vishay or any other equivalent capacitor confirming to is:13340 with ISI mar/47261361/106953677 |
Ministry of Railways |
-- |
| 11789. |
18-Feb-2026 12:11 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Floor drain traps/S.S. Seamless pipe/LN265247/106973336 |
Ministry of Railways |
-- |
| 11790. |
18-Feb-2026 12:39 PM |
11-Mar-2026 02:30 PM |
11-Mar-2026 02:30 PM |
Light Weight Push Trolley/95265085/106973419 |
Ministry of Railways |
-- |