Central - Tenders Closing for a specific Date

Report For Day : 23-Jan-2026

Total Tenders : 1992
Sl.No e-Published Date Bid Submission Closing Date Tender Opening Date Title/Ref.No./Tender Id State Name Corrigendum
1141. 13-Jan-2026 03:47 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM Supply of armoured OFC 24 fiber cable as per RDSO specification no RDSO specs No IRS TC-55/2006 (rev. 1) with amendment 3 or latest amendment./TS265033/106939224 Ministry of Railways --
1142. 13-Jan-2026 03:54 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM Supply of CALLING-ON ASPECT LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/153/2011 (Rev.4.1) or latest.Signal aspect LED signal unit, 110V AC with health monitor alarm unit having lamp proving output to drive LED Lamp Proving Relay, the complete unit conforming to RDSO Specification No. RDSO/SPN/153/2011 REVISION 4.1 or with latest amendment or to the latest specification of LED Signal aspects and t/TS265032/106939246 Ministry of Railways --
1143. 13-Jan-2026 04:00 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM Colour light signal LED signal Main LED signal lighting unit 110V AC LED Signal YELLOW aspect Integrated type rectrofittable in existing CLS housing and compatib YELLOW LED MINIATURE TYPE FOR TUNNEL SPEC RDSO/SPN/153 2023 REV 5.0, STR: SIQ 0204 VER 0, (YELLOW)le with AC LED ECR as per RDSO specn.No.RDSO/SPN/199/2010 Revision 1.1Signal aspect LED signal unit, 110V AC with health monitor alarm unit having lamp proving output to drive LED Lamp Proving Relay, the complete unit conforming to RDSO S/TS265031/106939268 Ministry of Railways --
1144. 13-Jan-2026 04:15 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM 1. (HSN-40169330) Rubber Kit for A9 Brake Valve of Rake Test Rig (RTR) to SSWAHA Part No. SST/SP01. Make: SSWAHA or MASTERLUBE 2. (HSN-40169330) Rubber Kit for C2W Relay Valve of Rake Test Rig (RTR) to SSWAHA Part No. SST/SP02. Make: SSWAHA or MASTERLUBE 3. (HSN-40169330) Rubber Kit for C2N Feed Valve of Rake Test Rig (RTR) equivalent to SSWAHA Part No. SST/SP03. Make: SSWAHA or MASTERLUBE 4. (HSN-90319000) A9 Brake Valve for Rake Test Rig (RTR) to SSWAHA Part No. SST/DBV. Make: SSWAHA or MAST/TS265035/106939320 Ministry of Railways --
1145. 13-Jan-2026 04:52 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM AUXILIARY ALTERNATOR 18.5KW 110V WITH PULLEY AND RECTIFIER CUM REGULATOR UNIT SITABLE FOR 1400HP DEMU/NJ265002/106939384 Ministry of Railways --
1146. 13-Jan-2026 04:53 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM 18.05KW RECTIFIER CUM REGULATOR OF MAGNETIC TYPE AND INBUILT OVER VOLTAGE PROTECTION RELAY AS PER KELDRAWING NO.18-A3030 ALT 3OR SIMILAR SUITABLE FOR 1400HP DEMU DPC.MAKE- BHEL /CGL/BHEL EML/KEL. MATERIAL TO BE PROCURED FROM OEM OR AUTHORIZED DEALER OF OEM ONLY ./NJ265003/106939390 Ministry of Railways --
1147. 13-Jan-2026 04:54 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM SUPPLY AND COMMISSIONING OF IGBT BASED CONSTANT CURRENT/CONSTANT VOLTAGE BATTERY CHARGE / DISCHARGE PANEL (155 V-100A), OUTPUT VOLTAGE ADJUSTABLE FROM 40 V TO 155 V AND OUTPUT CURRENT ADJUSTABLE FROM 10 A TO 100 A SUITABLE FOR CHARGING DISCHARGING OF 500 AH BATTRIES AS PER RDSO SPECN NO : RDSO/PE/SPEC/AC/0008 (REV. 2) APRIL 2010. N.B.: FIRM SHOULD HAVE PROTOTYPE CLEARENCE FROM RDSO FOR THE SAME CAPACITY CHARGERS. MATERIAL SHOULD BE PROCURE THROUGH RDSO APPROVED SOURCES ONLY WITH OEM TEST CERT/NJ265004/106939398 Ministry of Railways --
1148. 13-Jan-2026 04:54 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM Power Contactor, 3 pole, 1000V AC 800A, 50HZ, Suitable for 500KVA, 750V AC on load switchingunder AC -6a catageory at tempreature of 70 Degree C & coil Voltage of 110V+ 25 Percent -30 Percent (48-130 Volt) DC with Surge Suppressor, 2NO+2NC, According to bill of Material o f RDSO spec No RDSO/PE/SPEC/D/TL/0195-2019 (rev-0) similar to ABB make Model No AF1250-30-11, make- ABB/Siemens/Scneider or equivalent. material should be same in dimension as ABB make Model No AF1250-30 material procured/NB265045/106939405 Ministry of Railways --
1149. 13-Jan-2026 05:49 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM JACKET TYPE THERMAL INSULATION KIT FOR MODIFIED EXHAUST TRANSFER CONNECTIONS ( RIGHT BANK & LEFT BANK) OF 1600HP DEMU DPC FITTED WITH M/S- CUMMINS INDIA LIMITED MAKE DIESEL ENGINE OF MODEL QSK 50L.MATERIAL MUST CONFORM TO RDSO SPEC NO: MP.0.2600.24,SEPTEMBER 2009 (REVISION 0.01)-ANNEXURE III AND MUST HAVE ADDITIONAL SS MESH REINFORCEMENT ON INNER SIDE TO ENHANCE TEMPERATURE ENDURANCE ./NJ265010/106939585 Ministry of Railways --
1150. 13-Jan-2026 06:31 PM 23-Jan-2026 02:30 PM 23-Jan-2026 02:30 PM Spring loaded switch/20263816B/106939668 Ministry of Railways --

Note : For more details and clarifications, please refer to the respective Portal.